Key Features & Performance
- Sustainable Beyond Standard: FINALE PB custom size panels in 1" thickness and all standard FINALE PB panels are part of the SUSTAIN portfolio and meet the most stringent industry sustainability compliance standards today
- 1” thick panels with 1” factory-applied furring are sold by the piece - get the quantity you need without extra material
- Built-in furring pieces with factory-filled panels provide maximum sound control and install 2.5x faster than Direct-Attach for the same acoustic performance
- UL® Certified acoustics with acoustical testing and reporting that align with industry-wide best practices
- Excellent sound absorption – NRC up to 0.85 (mounting method dependent)
- CLEANASSURE family of products – includes disinfectable panels, suspension systems, and trim (standard colors)
- Panel sizes include 23-3/4" x 48", 23-3/4" x 96", 47-3/4" x 48", and 47-3/4" x 96", with bevel on long edges, square on short sides
- Custom panels are available in additional sizes and thicknesses upon request
- Abuse resistant for active spaces
- Can be mechanically fastened to a wide variety of surfaces including masonry, drywall, wood, and more
Material
Materials
TECTUM Wood Fiber
Acoustics
NRC Rating A Mounting
0.80
NRC Rating D-20 Mounting
0.85
Fire
Fire Performance
Class A (UL)
Class A (painted) / Class B (laminate)
Class A (painted) / Class B (laminate)
Light
Light Reflectance
A high light reflective ceiling – LR 0.83 or greater, per ASTM E1477-98 as referred to in ASTM E1264-98 – makes lighting systems, especially indirect lighting, more effective while further reducing energy costs and consumption. LR values apply to White panels only.
75%
Humidity
Sag/Humidity Resistance
Ceiling panels maintain humidity and sag resistance.
Standard
Durability
Impact Resistance
Surface impact based on the Striking Ball Impact Test, modified ASTM D1037 procedure.
Scratch Resistance
Excellent resistance to surface scratching, scuffing or chipping as per Hess Rake Test.
Disinfectability
Fog
May be fogged following CDC recommendations using EPA-approved disinfectant cleaners per Armstrong Cleaning & Disinfecting Guidelines
Made In U.S.A. Of Domestic and Global Content
Yes
Sustainability Profile
LEED • WELL • Living Building Challenge
Recyclable/Extended Producer Responsibility
|
FSC (for wood)
|
Energy Management
|
Recycled Content
|
Construction Waste
|
Sourcing of Raw Materials
|
Regional Materials
Location Dependent
|
Material Ingredient Reporting
|
Design for Flexibility
|
Low emitting/materials
|
EPD
|
Lighting Quality
|
Biobased Materials
|
Acoustics
|